The Ghost in Your IT Closet

Key Points
  • Surveys suggest that nearly 30 percent of servers are unused, wasting energy and money.
  • Consolidating applications onto fewer servers will help you reduce power requirements.
  • Lower cooling costs by improving airflow management and adjusting air handling fan speeds.

Server room ghostServer rooms use a lot of energy, but what's really scary is much of this energy's wasted. The Uptime Institute estimates nearly 30 percent of servers are unused.

While these servers may be idle, they may still be haunting your annual budget for up to $4,000 in energy and maintenance costs. That kind of waste doesn't compute with a healthy bottom line. Fortunately, there are a number of cost-saving measures you can take to help contain server room energy use.

Consolidate. Regularly inventory servers to track the number of applications running on each. Identify unused servers or units with low utilization. Consolidate, reassign or switch off servers to optimize usage.

Go virtual. Traditionally, one physical server was used for each application. Virtualization uses software to convert one server into a virtual machine performing multiple tasks. It allows you to combine processing power into fewer units operating at a higher capacity. This not only reduces energy consumption and waste heat, but also saves space and improves scalability.

Install variable frequency drives. Server room air handling fans consume a lot of power. Most fans run at a constant speed, while server load fluctuates. Variable frequency drives save energy by adjusting fan speed according to demand.

Economize. An air-side economizer brings in cool outside air and distributes it to the servers, reducing the need for air conditioning. The economizer is integrated into the central air handling system, with ducting for intake and exhaust air. Because servers must be cooled continuously, economizers are effective even in hot climates, where they can take advantage of cooler evening temperatures.

Hot aisle cold aisle servers

Raise the server inlet air temperature. ASHRAE recommends a server inlet temperature of 65°F to 80°F, yet many server room operators set temperatures as low as 55°F. You can save a significant amount of energy by raising the thermostat to within the recommended temperature range.

Manage airflow. Servers typically take in cold air through the front and exhaust hot air out the back. Arrange servers in parallel rows so the front of the servers are facing each other. This improves air flow and reduces the need for cooling. Hot aisle/cold aisle arrangements can reduce air handling fan energy use by up to 25 percent, according to the U.S. Department of Energy.

When you replace older servers, purchase ENERGY STAR certified units. ENERGY STAR® servers are 30 percent more energy efficient than standard models and deliver more processing power.

more Share
Share & BookmarkX
|
Share This Link With A Friend
Content provided for Johnson County REMC customers, Powered by Questline RelationshipBuilder. © Questline Inc.
Acceptable use and linking guidelines for this article
How would you rate the quality of this content?  Select a star rating and click submit below.
Comments or suggestions for additional content: (optional)
 

This message was sent by Johnson County REMC - 750 International Drive - Franklin - IN - 0